Overview HXGN15-12 interval-type mental-enclosed switchgear is the complete indoor switchgear of three-phase AC 50Hz. It is used for receiving and distributing 7.2~12kv network power as well as protecting and monitoring the electric circuit. It is a new complete equipment of gas insulated. With our continuous improvement, we had made its perfect function and flexible assembling adaptable to the changing market. Have perfect "five-prevention" function and functional program. It can be installed in indoor distribution room YBM outdoor ring box and HDKF with FLN36 FLN48 SFG LK-GLBS and other types of SF6 switch-disconnector. Products comply with GB3906 DL/T404 and IEC60298and other standards. Product technical characteristics: Cabinet structure was made by mental plate bended and assembled TIBNOR and SECC Flexible choose of main switchgear: you can choose ABB TE LKE and other famous SF6 switch-disconnector, you can also choose the mature products in our country. SF6 as extinguishing medium, breaking performance is stable and quality reliable. High forest density of the cabinet shell, to prevent the sundries and insect pest, protection level IP3X Easy but effective shutting, prevent wrong operations (five prevention) Can be installed with fuse plug remote displayer VPIS short-circuit indicator RGFI gel control Can be installed with NCS, realize the distribution automation The cabinet can be operated and repaired before itself, reduce the floor area HSGS is used for landing and backing to the short road Pasted the trial under harsh climate conditions Product technical parameter No. Item item unit technical parameter 1 rated voltage KV 12 2 rated insulation level 1 one minute power frequency withstand voltage KV 42 (interphase relatively), 48 (isolated port) 2 peak withstand voltage 75 (interphase relatively), 85 (isolated port) 3 rated current A 630 4 I cw (RMS) kA/s 20/2 5 peak withstand current (peak value ) kA 50 6 level of protection IP3X 7 dimensions (W × D × H) mm 375/500×900×1850 8 fuse with the maximum current A 200 9 fuse with the rated short-circuit breaking current kA 31.5 10 transfer current A 1700 11 rated closed-loop breaking current A 630 Ordering instruction: Main wiring program number or single systematic plan, Floor plan The secondary diagram, wiring terminal arrangement diagram (if none, arrange according to our rule) electrical components' model number, specifications and quantity of Switch cabinet Summary of electrical equipment provide span and height dimensions when bus bridge is needed (bus bridge between two cabinets or between wall and cabinets; notify us before order if Switchgear is to be used in the special environmental conditions Other special requirements. |
See more products from this supplier.
Do you want to show products of your own company? Join FREE now!